> PRODUCTS
Get A Quote

TCLMA-D1 Liquid Nitrogen Monitoring & Alarm System

liquid nitrogen monitor
liquid nitrogen level measurement
liquid nitrogen tank monitoring
liquid nitrogen level indicator
liquid nitrogen monitor
liquid nitrogen level measurement
liquid nitrogen tank monitoring
liquid nitrogen level indicator

Remote Liquid Nitrogen Level and Temperature Monitoring

The TcCryo TCLMA-D1 Liquid Nitrogen Monitoring & Alarm System monitors liquid nitrogen level and temperature in compatible cryogenic storage equipment. It combines local display, APP/Web remote access, historical data recording, and configurable abnormal-condition alerts to help users monitor storage status and plan routine maintenance.

The system uses a separate monitoring unit and external probe, with Wi-Fi connectivity and USB or battery power options. It can continue local data recording during a network interruption, subject to its supported operating conditions.

Designed for applications such as laboratories and biological sample storage facilities, the TCLMA-D1 helps users access monitoring information without relying solely on manual checks.

                       
Chat Now DISCOVER NOW

Core Monitoring and Data Management Functions

  • 01

    Liquid Nitrogen Level and Temperature Monitoring

  • The TCLMA-D1 monitors liquid nitrogen level and temperature in compatible storage equipment, providing information to support routine checks and refill planning.
  • 02

    APP / Web Remote Access

  • View available monitoring data, trend curves, historical records, and alarm records through the supported mobile APP or web interface.
  • 03

    Configurable Abnormal-Condition Alerts

  • The system supports alerts for specified conditions, including abnormal liquid nitrogen levels, high or low temperature, low battery, external power interruption, and device offline status, according to the available settings.
  • 04

    Local Data Recording During Network Interruptions

  • The device can continue recording data locally during a Wi-Fi interruption. Data synchronization after reconnection depends on the system's supported synchronization function.
  • 05

    The built-in LCD display supports up to 100,000 sets of local data records

  • The device can continue recording data locally during a Wi-Fi interruption. Data synchronization after reconnection depends on the system's supported synchronization function.The built-in LCD display supports up to 100,000 sets of local data records.
  • 06

    USB and Battery Power Options

  • The system supports USB power and two 18650 rechargeable batteries. Actual battery operating time depends on the device's operating and data-reporting conditions.
liquid nitrogen tank alarm

PARAMETER

Type TCLMA-D1
sensor type 2 meters per external
Temperature measurement range -200℃~200℃
Temperature measurement accuracy ±0.3℃
Local storage capacity 100,000 groups
Measuring resolution Temperature: 0.1 ℃
Output Interface WIFI ,USB
battery capacity Two knots 6000mAh
Rated voltage USB power supply: 5V / 18650 battery power supply: 3.7V
Consumption Average: 2mA (report once every 10 minutes)
Effective working area Average: 2mA (report once every 10 minutes)

Compare Liquid Nitrogen Monitoring Options

Different liquid nitrogen storage applications require different levels of monitoring and data management.

Feature Liquid Nitrogen Level Gauge TCLMA-D1 Monitoring & Alarm System Smart Neck Plug
Monitoring method Manual measurement Electronic monitoring Integrated electronic monitoring
Level viewing On-site Local / Remote Local / Remote
Temperature monitoring Depends on gauge type Supported Confirm by model
Abnormal-condition alerts Not typically available on a manual gauge Supported Confirm by model
Historical data Not typically available on a manual gauge Supported Confirm by model
Remote access Not typically available on a manual gauge APP / Web Confirm by model
Installation Depends on gauge design Separate unit and external probe Integrated neck-plug

configurationChoose a monitoring option based on your required functions, existing tank configuration, and data management needs. Smart Neck Plug functions and compatibility should be checked against the specific model.

Installation and Setup

Installation Workflow

Confirm Installation Position → Mount the Main Unit and Probe → Install Batteries or Connect USB Power → Bind the Device and Configure Wi-Fi → Set Monitoring and Alarm Parameters → Check Data and Alarm Status

The TCLMA-D1 uses a separate monitoring unit and external probe. The probe position should be determined according to the tank structure and the intended monitoring function.

Before routine operation, verify that the device is connected, the displayed readings are available, and the configured alarm functions operate as expected.

Installation and Use Considerations

Choose a Suitable Installation Location

Avoid exposing the main unit to direct sunlight, heat sources, or conditions outside its specified operating environment.

Protect the Main Unit from Moisture

Avoid prolonged exposure to water mist, spray, vapor, or condensation unless the device is specifically rated for those conditions.

Check Power and Network Status

Check the battery level, external power supply, and Wi-Fi connection as part of routine equipment checks.

Verify Operation After Adjustments

After changing the probe position or alarm settings, confirm that the readings and alert functions remain appropriate for the tank and monitoring requirements.

Continue Routine Tank Maintenance

The monitoring system provides status information and alerts but does not replace liquid nitrogen replenishment, tank inspection, or other required maintenance procedures.

Related Products

Laboratory Series Aluminum Dewars

Aluminum liquid nitrogen storage containers designed for laboratory sample storage. Explore available capacities and configurations for your storage requirements.

Liquid Nitrogen Tanks for Artificial Insemination (1–50 L)

Compact liquid nitrogen containers for storing and transporting frozen semen in livestock breeding and artificial insemination applications. Choose a suitable capacity based on sample quantity and handling requirements.

Smart Neck Plug

An integrated monitoring solution for liquid nitrogen level and temperature, helping users access storage status and manage monitoring tasks.

Liquid Nitrogen Tank Trolley

A practical handling accessory for moving compatible liquid nitrogen tanks within laboratories and other working environments. Check tank dimensions and trolley compatibility before selection.


Get a Liquid Nitrogen Monitoring Solution

Need help selecting a monitoring solution for your liquid nitrogen tank? Share your tank model and required monitoring functions so TcCryo can help assess a suitable configuration.

Frequently Asked Questions

Q1: Can the TCLMA-D1 be installed on an existing liquid nitrogen tank?
Yes. The TCLMA-D1 can be installed on existing liquid nitrogen tanks. Simply attach the sensor probe to the sample storage rack or canister inside the tank to monitor the liquid nitrogen level and temperature.
Q2: Can multiple tanks be monitored by multiple users?
Yes. The monitoring platform supports multiple devices and user access, allowing authorized users to view data from multiple tanks. User accounts and access permissions can be configured according to your monitoring needs.
Q3: Can monitoring data be exported for laboratory records?
Yes. Users can access and export real-time data, temperature trend curves, alarm logs, and historical records through the Web platform or mobile APP for laboratory recordkeeping.
Q4: What should I do when the system sends a level or temperature alert?
Check the reported readings through the monitoring platform and verify the tank's actual liquid nitrogen level and temperature. If the readings indicate insufficient liquid nitrogen or an abnormal temperature, follow the appropriate replenishment or sample-protection procedures. If the readings appear inconsistent with the tank's actual condition, check the probe installation and device status.
Q5: What is the warranty period for the TCLMA-D1?
The TCLMA-D1 comes with a 12-month warranty, subject to TcCryo's applicable warranty terms and conditions.
Q6: Does the monitoring system need to be checked after being moved to another tank?
Yes. After moving the TCLMA-D1 to another tank, check the probe position and installation, then verify the level and temperature readings against the tank's actual condition. Also confirm that the alarm thresholds are appropriate for the new application before resuming routine monitoring.