> PRODUCTS
Get A Quote

Lab-3 / Lab-4 Dewars for Cryogenic Processing

Lab-4
Lab-4 Bottom vacuum port
Lab-3
Lab-4
Lab-4 Bottom vacuum port
Lab-3

Compact Aluminum Dewars for Cryogenic Grinding, Sample Pre-Cooling, and Laboratory Sample Preparation

TcCryo Lab-3 and Lab-4 are designed for laboratory cryogenic processing applications, including cryogenic grinding, sample pre-cooling, low-temperature material treatment, and routine small-volume liquid nitrogen handling.

With a compact aluminum design and side handles, these dewars provide convenient access to liquid nitrogen for pouring and handling during routine laboratory procedures. They are suitable for research, testing, and R&D laboratories that require liquid nitrogen for sample preparation and other low-temperature processes.

                       
Chat Now DISCOVER NOW

Core Features & Benefits

Designed for Routine Liquid Nitrogen Handling and Cryogenic Processing

  • 01

    Compact Design for Laboratory Workstations:

  • Available in 3.15L and 4.00L capacities, Lab-3 and Lab-4 feature compact aluminum vessels with side handles for convenient handling near laboratory workstations. Their different dimensions allow users to select a model according to liquid nitrogen requirements and available workspace.
  • 02

    Side Handles for Convenient Handling and Pouring:

  • The side handles provide a convenient grip when handling and pouring liquid nitrogen during routine laboratory procedures. They support controlled manual dispensing when adding LN₂ to compatible grinding containers, sample vessels, or other laboratory equipment..
  • 03

    High-Vacuum Insulation:

  • The high-vacuum insulation structure helps reduce heat transfer from the surrounding environment and minimize natural liquid nitrogen evaporation. Refer to the model specifications for static evaporation performance.
Lab-3 / Lab-4 Dewars for Cryogenic Processing

How to Choose Between Lab-3 and Lab-4

Both models are designed for similar laboratory cryogenic processing applications. The main selection factors are the liquid nitrogen volume required per operation, operating frequency, and available laboratory space.

Choose Lab-3 When

With a 3.15L capacity and a taller, narrower body, Lab-3 may suit workflows requiring a smaller liquid nitrogen volume per operation or a narrower benchtop footprint, provided sufficient vertical clearance is available.

Choose Lab-4 When

With a 4.00L capacity and a shorter, wider body, Lab-4 may suit workflows requiring a larger liquid nitrogen volume per operation, provided sufficient benchtop width is available.

For practical model selection, consider the required liquid nitrogen volume per operation, handling frequency, and available workspace together.

Lab-3 / Lab-4 vs. Laboratory Liquid Nitrogen Storage Tanks

Lab-3 and Lab-4 are primarily designed for liquid nitrogen handling during laboratory processes. Laboratory liquid nitrogen storage tanks, by contrast, are designed for long-term cryogenic storage of biological samples.

Application Lab-3 / Lab-4 Laboratory LN₂ Storage Tanks
Cryogenic grinding and sample pre-cooling Designed for this purpose Not the primary application
Small-volume liquid nitrogen handling Suitable Depends on model and workflow
Long-term cryovial storage Not the primary application Designed for this purpose
High-density biological sample storage Not the primary application Suitable models available

The key selection factor is not simply container capacity, but what the liquid nitrogen is primarily being used for.

Models & Technical Specifications

Lab-3 and Lab-4 Technical Comparison

Compare the two models by capacity, dimensions, and static cryogenic performance to identify a suitable dewar for your laboratory workflow.

Model Lab-3 Lab-4
LN₂ Capacity (L) 3.15 4.00
Static Evaporation Rate (L/day) 0.10 0.16
Static retention period (Day) 30 25
Neck Opening (mm) 35 35
Overall Height (mm) 520 475
Outer Diameter (mm) 180 224

Actual performance depends on the specified test conditions and operating practices.

Understanding the Key Specifications

Liquid Nitrogen Capacity

Indicates the nominal amount of liquid nitrogen the vessel can hold. Select a capacity based on the volume required per operation and the frequency of liquid nitrogen use.

Static Evaporation Rate

Measures natural liquid nitrogen loss under specified test conditions. It provides a reference for comparing the static performance of the two models.

Static Holding Time

Indicates the reference holding time measured under specified conditions. It should not be interpreted as a guaranteed operating period when the dewar is frequently opened, poured, or handled.

Overall Dimensions

The Lab-3 is taller and narrower, while the Lab-4 is shorter and wider. Consider the available benchtop footprint and vertical clearance when selecting a model.

Actual liquid nitrogen consumption may vary with ambient conditions, fill level, lid-opening frequency, pouring frequency, and operating practices.

Use & Safety Guidelines

When using a liquid nitrogen dewar, follow appropriate laboratory cryogenic handling procedures:

Ensure adequate ventilation. Evaporating nitrogen can displace oxygen and create an oxygen-deficient atmosphere.

Wear appropriate protective equipment. Use suitable cryogenic gloves and a face shield or safety goggles when handling liquid nitrogen.

Avoid direct contact. Prevent liquid nitrogen from contacting skin and avoid touching cold surfaces without appropriate protection.

Keep the dewar stable. Avoid dropping, impact, tipping, or rough handling.

Keep venting paths unobstructed. Never seal a liquid nitrogen container or obstruct its designed venting path.

Follow the product instructions. Observe the manufacturer's guidance for filling, pouring, handling, and maintenance.

Follow equipment-specific procedures. When using liquid nitrogen for cryogenic grinding or other laboratory processes, follow the operating instructions for the relevant equipment and workflow.

Related Products

Aluminum Lab dewars

Designed for long-term cryogenic storage of cryovials and other biological samples.

Vapor-Phase / Liquid-Phase Cryogenic Storage Systems

Designed for larger-scale biological sample storage and smart storage management.

LN2 Supply Tanks

Designed for liquid nitrogen storage, transfer, and supply.

Liquid Nitrogen Tank Accessories

Including liquid-level monitoring devices, tank carts, and other supporting accessories.



Need Help Choosing the Right Dewar?

Tell us your main application and required quantity, and TcCryo will help identify a suitable Lab-3 or Lab-4 model for your laboratory workflow.

If you have OEM, packaging, project documentation, or other purchasing requirements, please include them in your inquiry.→Get a Quote

Frequently Asked Questions

Q1: Does Lab-3 / Lab-4 need to be pre-cooled before first use?
Yes. Before the first filling, allow the container to cool gradually according to the product manual. This helps reduce rapid liquid nitrogen boil-off when the container is initially cooled.
Q2: What should I check before using Lab-3 / Lab-4?
Before use, inspect the container body, side handles, and connecting parts for visible damage or deformation. Stop using the container if any abnormal condition is found, and have it checked before further use.
Q3: Does frequent use affect the static holding time of Lab-3 / Lab-4?
Yes. Static holding time refers to the time it takes for the liquid nitrogen to evaporate completely after the container has been filled, with the lid kept closed and no liquid nitrogen being dispensed or used.
During actual use, repeated opening and liquid nitrogen dispensing increase heat input, causing liquid nitrogen to evaporate more quickly. Therefore, the actual holding time may be shorter than the stated static holding time.
Q4: Can Lab-3 / Lab-4 be customized for specific requirements?
Contact TcCryo if you have specific requirements for product configuration, OEM customization, or technical documentation. Available customization options depend on the requested changes and technical requirements.
Q5: What information should I provide when requesting a quote for Lab-3 / Lab-4?
To help us prepare an accurate quotation, provide your preferred model and required quantity. Include any additional requirements for OEM customization or technical documentation in your inquiry.