The TcCryo Liquid Nitrogen Biological Sample Transfer Cart is designed for batch sample handling and transfer in laboratories, biobanks, and other life science facilities.
Combining a sample handling workspace, temperature monitoring, and a liquid nitrogen transfer connection in one mobile unit, it supports the handling and transfer of biological samples, including cells and tissues.

| Specification | Value |
| Performance | |
| Total LN₂ Capacity (L) | 53 |
| 2 mL Cryovial Capacity | 3,000 |
| Top Temperature with Lid Open (°C) | -150 |
| Number of 15-Layer, 100-Position Cryobox Racks | 2 |
| Continuous Operating Time with Lid Closed (h) | 18 |
| Dimensions & Weight | |
| Overall Length (mm) | 1,313 |
| Overall Width (mm) | 447 |
| Overall Height (mm) | 900 |
| Inner Length (mm) | 1,040 |
| Inner Width (mm) | 340 |
| Inner Depth (mm) | 400 |
| Table Height (mm) | 152 |
The nominal liquid nitrogen capacity is **53 L**. This refers to the liquid nitrogen volume the vessel is designed to hold, not the available space for sample containers.
The maximum stated capacity is **3,000 2 mL cryovials** under the specified loading configuration. Actual loading capacity varies with container dimensions, rack arrangements, and alternative loading requirements.
The specified operating time is up to **18 hours with the lid closed**. This figure is subject to the applicable test and operating conditions and should not be interpreted as a guaranteed duration under all loading and environmental conditions.
The dual-channel Type-T thermocouples provide two-channel temperature monitoring. The monitored locations and applicable temperature ranges should be confirmed according to the product configuration.
The standard configuration includes:
- Dual-channel Type-T thermocouples
- Liquid nitrogen transfer hose connection
- Ball valve
- Safety valve
*Standard configuration and available options should be confirmed against the specified product model.*
Confirm that cryovials, cryoboxes, racks, and blood bags match the specified loading configuration before use.
Use the dual-channel Type-T thermocouples to monitor temperature during operation and follow the applicable operating procedures.
The specified operating time of up to 18 hours applies with the lid closed. Frequent opening may affect operating performance.
Use appropriate personal protective equipment and follow established safety procedures when filling, transferring, or handling liquid nitrogen.
Confirm that the liquid nitrogen transfer hose and associated connections are compatible and properly installed before operation.