Portable Cryogenic Sample Transport Container

Product Overview:

The TcCryo Portable Cryogenic Sample Transport Container is designed for small-batch, short-distance transfer of temperature-sensitive samples within hospitals, laboratories, and research facilities.

Its compact, hand-carry design provides a practical solution for moving compatible cryogenic sample tubes between designated storage, processing, and laboratory areas.

                       
Chat Now DISCOVER NOW

Key Features

  • 01

    Vacuum-Insulated Structure:

  • The vacuum-insulated construction, combined with thickened insulating materials, helps reduce heat transfer and maintain low-temperature conditions during sample transfer.
  • 02

    Liquid Nitrogen Splash-Control Design:

  • The integrated splash-control structure is designed to help reduce liquid nitrogen splashing during movement. Follow the manufacturer's instructions for filling and handling.
  • 03

    Condensation-Protection Lid:

  • The specially designed lid helps prevent external condensation from flowing back into the container and supports convenient opening during routine use.
  • 04

    Bottom Liquid Nitrogen Absorption Layer:

  • The bottom absorption layer is designed to retain liquid nitrogen under the specified operating configuration. Its use should follow the manufacturer's instructions.
Portable Cryogenic Sample Transport Container

Technical Specifications

Detailed technical specifications for the YDT-2 and YDT-2S are provided in the table below.

Specification YDT-2 YDT-2S
Capacity 2 L 2 L
Outer Diameter 158 mm 158 mm
Height 250 mm 268 mm
Neck Diameter 126 mm 126 mm
Vapor-Phase Holding Time 6 h 6 h
Liquid-Phase Holding Time 8 h 8 h
Compatible Cryovial Sizes 1.2 mL, 1.5 mL, 1.8 mL, 2.0 mL, 5.0 mL 1.2 mL, 1.5 mL, 1.8 mL, 2.0 mL, 5.0 mL
Cryovial Capacity 54 vials 55 vials

Safety & Handling Notes

Wear suitable cryogenic gloves and eye protection when handling liquid nitrogen.

Use liquid nitrogen in adequately ventilated areas.

Follow the manufacturer's instructions for filling, carrying, and operating the container.

Use the bottom absorption layer and liquid nitrogen management features only in the specified operating configuration.

Plan sample transfers according to the applicable holding time and actual operating conditions.

Handling Precautions

Secure the sample tubes before movement.

Ensure that sample tubes are properly positioned in the compatible internal holders or accessories to prevent displacement during transfer.

Follow the specified liquid nitrogen filling procedure.

Allow the container to stabilize after filling and follow the manufacturer's instructions before moving it.

Use the splash-control and absorption features as instructed.

These structures are designed to assist liquid nitrogen management during handling but should not replace proper operating procedures.

Keep the transfer within the specified holding time.

Plan sample movement according to the applicable gas-phase or liquid-phase holding time and actual operating conditions.

Check the container before use.

Inspect the lid, sample holders, and relevant components for proper installation and visible damage before each transfer.

Frequently Asked Questions

Q1: What is the difference between the YDT-2 and YDT-2S?
The main difference is the configuration. The YDT-2S includes temperature monitoring and accommodates one additional 2 mL cryovial. Choose the YDT-2 for basic sample transfer without temperature monitoring, or the YDT-2S if temperature monitoring is required during transfer.
Q2: How long can the container maintain cryogenic conditions during sample transfer?
The specified holding times are 6 hours in gas-phase operation and 8 hours in liquid-phase operation. Actual performance may vary depending on ambient temperature, filling conditions, opening frequency, and handling practices. Plan sample transfers according to the applicable holding time and actual operating conditions.
Q3: How can I confirm whether my sample tubes are compatible?
Compatibility depends on the dimensions of the sample tubes, cap design, and internal storage configuration. The container accommodates up to 54 or 55 pieces of 2 mL cryovials, depending on the model. If you use different tube sizes or specific cryovial types, provide their dimensions and required quantities to TcCryo for configuration confirmation.
Q4: What temperature monitoring functions does the YDT-2S provide?
The YDT-2S is equipped with a temperature monitoring function. Additional capabilities, such as temperature alarms, data logging, remote monitoring, and measurement accuracy, should be confirmed with TcCryo before ordering to ensure the monitoring configuration meets your application requirements.
Q5: Can the YDT-2 and YDT-2S be used for long-distance sample shipping?
The YDT-2 and YDT-2S are designed primarily for small-batch, short-distance transfers within hospitals, laboratories, and research facilities. Their suitability for courier services, long-distance shipping, or air transport should be evaluated separately based on the transport method, applicable regulations, and required holding time.