TcCryo Participates in the 2026 Nanjing Analytical and Biochemical Instrument Exhibition
On October 27, 2026, representatives of Henan Tianchi Cryogenic Machinery Equipment Manufacturing Co., Ltd. participated in the 2026 Huaxia Analytical and Biochemical Instrument Exhibition in Nanjing, China. Organized by Instrument Knowledge Network, the event brought together professionals from the analytical and biochemical instrument industry for product exhibitions, industry exchanges, and business discussions.
As a manufacturer of liquid nitrogen equipment, TcCryo participated in the conference and shared insights into liquid nitrogen tank selection, performance evaluation, and purchasing considerations. Rather than focusing solely on product specifications, the discussions addressed how buyers can evaluate equipment based on their actual storage requirements, operating conditions, and long-term management needs.

1. Choosing the Right Equipment: Consider Sample Volume and Management Needs
Selecting a liquid nitrogen storage solution involves more than comparing nominal capacity. Sample quantity, storage method, access frequency, and management requirements all influence the choice of equipment.
1.1 Conventional Laboratory Tanks vs. Biobank Storage Systems
Conventional laboratory liquid nitrogen tanks, such as those in the YDS series, are commonly used for routine sample storage in laboratories and research facilities. Their configurations can be selected according to sample capacity, neck opening, and compatible racks or canisters.
For facilities managing larger sample collections or requiring more structured storage operations, an automated biobank storage system may be more appropriate. TcCryo’s YDD series offers configurations that support liquid-phase or vapor-phase storage, with functions such as temperature and liquid-level monitoring, alarms, automatic liquid nitrogen replenishment, and data management, depending on the model and configuration.
The key difference is not simply storage capacity. Buyers should also consider how samples will be accessed, monitored, and managed throughout daily operations.
1.2 Lab-65 vs. Cryobank 2400: Why Can Similar Capacities Require Different Equipment?
A 65L laboratory liquid nitrogen storage tank (Lab-65) and the Cryobank 2400 have similar liquid nitrogen capacities, but they are designed for different storage and management requirements.
The Lab-65 is a conventional laboratory liquid nitrogen storage tank designed for sample storage using compatible racks and canisters. Its configuration can be selected according to sample type and storage capacity requirements.
Cryobank 2400, by contrast, is a compact intelligent cryogenic storage system that supports both liquid-phase and vapor-phase storage. It integrates liquid-level and temperature monitoring, alarms, and other sample management functions. Automatic liquid nitrogen replenishment is also available when the system is connected to a compatible self-pressurized liquid nitrogen supply tank.
Therefore, similar capacities do not necessarily mean that two products serve the same purpose. The choice should depend on the required storage mode, sample management needs, and level of monitoring and automation.
2. Static Evaporation Rate and Liquid Nitrogen Management
Static evaporation rate is an important performance indicator when evaluating a liquid nitrogen storage tank. It reflects liquid nitrogen loss under specified test conditions and provides a reference for comparing the insulation performance of different containers.
However, the static evaporation rate should not be treated as the exact daily liquid nitrogen consumption under normal operating conditions. Actual consumption can also be affected by ambient temperature, opening frequency, the duration of each opening, and sample handling practices.
For this reason, buyers should review the stated test conditions and product specifications rather than relying on a single evaporation-rate figure.
Liquid-level monitoring accessories can also help users manage daily operations. For example, an intelligent stopper can monitor liquid level and temperature, while a liquid-level alarm can alert users when the level falls below a preset threshold. These functions support routine monitoring but do not replace performance testing.
3. Vacuum Warranty: Clarify Coverage and Terms Before Purchasing
Vacuum insulation is essential to the performance of a liquid nitrogen container. A vacuum-related warranty can therefore be an important consideration during equipment procurement.
However, buyers should not assume that the same warranty period and coverage apply to every model. Before placing an order, it is advisable to confirm:
Whether the selected model includes a vacuum-insulation warranty.
The warranty period and the specific components covered.
The conditions under which warranty service applies.
The procedures for inspection and after-sales support.
TcCryo offers a five-year vacuum warranty for selected models. The applicable models, coverage, and terms should be confirmed in the product documentation or purchase agreement.
4. Product Standards and Factory Documentation: Verify What Applies
Product standards and supporting documentation are important parts of equipment evaluation. However, different types of liquid nitrogen containers may fall under different standards depending on their materials, structure, capacity, and operating pressure.
Relevant Chinese national standards may include:
GB/T 5458-2012 – Liquid nitrogen biological containers.
GB/T 16774-2012 – Self-pressurized liquid nitrogen containers.
GB/T 14174-2012 – Large-opening liquid nitrogen containers.
These standards do not automatically apply to every type of liquid nitrogen equipment. For example, GB/T 5458-2012 specifies a scope that includes certain aluminum-alloy, atmospheric-pressure liquid nitrogen biological containers with effective volumes from 1 L to 175 L. A product’s actual applicability must be assessed against the standard’s requirements.
Similarly, GB/T 16774-2012 concerns self-pressurized liquid nitrogen containers and should not be treated as a general standard for conventional storage tanks.
During procurement, buyers should ask manufacturers to provide relevant technical documents and confirm which standards apply to the specific model. Depending on the product, these may include material specifications, inspection records, product test reports, and other supporting documentation.

5. From Product Selection to Delivery: Confirm Key Requirements in Writing
A clear purchasing specification helps reduce misunderstandings between buyers and manufacturers. Before confirming an order, both parties should agree on the following details:
Product model and configuration
Confirm the model, nominal capacity, neck opening, storage accessories, and the number and type of racks or canisters.
Storage and management requirements
Specify whether liquid-phase or vapor-phase storage is required, along with any monitoring, alarm, automatic replenishment, or data management functions.
Technical documents and inspection requirements
Clarify which product specifications, test records, inspection documents, and other technical materials will be supplied.
Packaging, delivery, and after-sales arrangements
Confirm packaging requirements, shipping arrangements, delivery schedules, installation or operating guidance where applicable, and warranty coverage.
For customized products, additional details such as interface dimensions, accessory compatibility, and special operating requirements should also be confirmed before production.
Clear communication at the purchasing stage helps ensure that the delivered equipment matches the buyer’s actual application requirements.
About TcCryo
TcCryo is a liquid nitrogen equipment brand of Henan Tianchi Cryogenic Machinery Equipment Manufacturing Co., Ltd. The company manufactures liquid nitrogen containers and cryogenic storage equipment for laboratory, life science, biobank, and animal breeding applications.
Its product portfolio includes laboratory liquid nitrogen tanks, biological sample storage systems, dry shippers, animal breeding containers, and liquid nitrogen supply tanks.
By combining product manufacturing, quality inspection, and application-oriented technical support, TcCryo works with distributors and end users to identify suitable equipment configurations for different storage requirements.
Conclusion
The discussions at the 2026 Nanjing Instrument Distributors Training Conference highlighted an important point: selecting liquid nitrogen equipment requires more than comparing capacity and price.
Storage mode, sample management, insulation performance, applicable standards, documentation, and after-sales terms all deserve attention before a purchasing decision is made.
TcCryo will continue to exchange practical experience with industry partners and support buyers in evaluating liquid nitrogen storage solutions based on their actual application needs.