Overview:
Designed for laboratory sample storage!
KGSQ liquid nitrogen cell storage tank, with a capacity ranging from 30 liters to 175 liters, can accommodate 750-6000 2ml cryopreservation tubes, 540-1800 5ml cryopreservation tubes, standard cryopreservation racks, cryopreservation boxes, liquid can be configured Nitrogen transfer tanks to help replenish liquid nitrogen, liquid level alarms to monitor the height of liquid nitrogen, trolleys to transfer containers, etc.
This series of liquid nitrogen containers has the characteristics of large capacity sample storage, large diameter and easy operation.
CHAT NOW DISCOVER NOWmodel | YDS-30-125 | YDS-35-125 | YDS-47-127 | YDS-50-125 | YDS-65-216 | YDS-95-216 | YDS-115-216 | YDS-130-216 | YDS-145-216 | YDS-160-216 | YDS-175-216 | YDS-190-216 |
Maximum storage capacity | ||||||||||||
Square bucket quantity | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
2.0 ml cryovial quantity (81/100 square bucket) |
—— | —— | —— | —— | 1944/2400 | 2430/3000 | 2916/3600 | 3402/4200 | 3888/4800 | 4374/5400 | 4860/6000 | 5346/6600 |
Quantity of 2.0 ml cryovials (25 square bucket) | 600 | 750 | 750 | 900 | —— | —— | —— | —— | —— | —— | —— | —— |
Number of layers of freezing racks | 4 | 5 | 5 | 6 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
performance | ||||||||||||
Volume (L) | 31.50 | 35.20 | 48.50 | 52.10 | 66.5 | 97.2 | 120.7 | 133.5 | 147.75 | 165.30 | 178.35 | 195.85 |
Static evaporation rate (L/day) | 0.35 | 0.35 | 0.42 | 0.45 | 0.78 | 0.81 | 0.85 | 0.85 | 0.85 | 0.87 | 0.87 | 0.89 |
Static liquid nitrogen storage period (d) | 90 | 100 | 115 | 115 | 85 | 120 | 142 | 157 | 173 | 190 | 205 | 220 |
Dimensions | ||||||||||||
Caliber (mm) | 130 | 130 | 130 | 130 | 216 | 216 | 216 | 216 | 216 | 216 | 216 | 216 |
Total height (mm) | 710 | 710 | 790 | 790 | 715 | 775 | 835 | 895 | 955 | 1015 | 1075 | 1135 |
Outer diameter (mm) | 440 | 440 | 516 | 516 | 680 | 680 | 680 | 680 | 680 | 680 | 680 | 680 |
Note: 1. The geometric volume/height/outer diameter/diameter and other values stated in the table are actual measured values. Due to the influence of measuring equipment/environment and other factors, there may be errors, and the error range does not exceed ±3%. 2. Static liquid nitrogen storage period: Under standard conditions (atmospheric pressure 101.325 kPa, ambient temperature 20 ℃), after the container is filled with liquid nitrogen, pre-cooled and reached thermal equilibrium, and the liquid nitrogen filling rate reaches 100%, it is placed statically until the liquid nitrogen The number of days until all evaporation occurs. 3. Static evaporation rate: After the container is left standing to reach thermal equilibrium under the specified filling rate, the mass of liquid nitrogen lost by natural evaporation within 24 hours is the percentage of the mass of liquid nitrogen contained in the effective volume of the inner tank, converted to the standard state (atmospheric pressure Evaporation rate value at 101.325 kPa, ambient temperature 20℃). |