Controlled-Rate Freezing Systems for Biological Sample Cryopreservation

TcCryo CX Series Controlled Rate Freezers are designed for controlled, programmable freezing of biological samples before long-term cryogenic storage. They support different sample formats, including cryovials, blood bags, and straws, depending on the model and compatible loading configuration.

By regulating the cooling process and monitoring sample or chamber temperature, the systems help laboratories follow defined freezing protocols for biological sample preparation. After the freezing cycle, samples can be transferred to suitable liquid nitrogen storage equipment according to the requirements of the application.

Designed for biobanks, cell therapy, life science research, and assisted reproduction applications, the CX Series offers different chamber configurations and capacities to accommodate varying sample formats and batch sizes.

                       
Chat Now DISCOVER NOW

Key Features

  • 01

    Programmable Freezing Profiles:

  • The system provides preset and user-defined programs to support freezing protocols for different sample types and processing requirements.
  • 02

    Sample and Chamber Temperature Monitoring:

  • Users can select sample-temperature or chamber-temperature control modes according to the freezing protocol and application requirements.
  • 03

    Controlled Cooling and Heating:

  • Adjustable cooling and heating rates allow users to configure the freezing process to suit established sample-processing protocols.
  • 04

    Multiple Chamber Configurations:

  • Side-opening and top-opening models accommodate different sample formats and loading arrangements. Select the configuration based on sample type, compatible holders, batch capacity, and available laboratory space.
  • 05

    Touchscreen Operation:

  • The touchscreen interface supports program selection, parameter setting, and process monitoring. Display size varies by model.
Controlled Rate Freezer Design

Models and Technical Specifications

Side-Opening Models

The CX Series includes side-opening and top-opening configurations for different sample formats and processing capacities.

Side-opening models:CX-17, CX-34, CX-37, and CX-51

Top-opening models: CX 26, CX 90, and CX 150

Compare the models based on sample format, loading configuration, batch capacity, chamber dimensions, and operating requirements.

Model CX-17 CX-34 CX-37 CX-51
Capacity
2 mL Cryovials 380 810 930 1,190
5 mL Cryovials 228 486 533 714
25/50 mL Blood Bags 30 60 60 90
250 mL Blood Bags 10 20 20 30
200 mL Blood Bag Boxes 10 20 — 30
700 mL Blood Bag Boxes 10 20 — 30
Performance
Temperature Range +50°C to -190°C
Overall Dimensions (mm) 860 × 540 × 550 1006 × 540 × 550 1046 × 540 × 550 1190 × 540 × 550
Internal Dimensions (mm) 180 × 305 × 330 330 × 305 × 330 370 × 305 × 330 502 × 305 × 330
Volume (L) 17 34 37 51
Net Weight (kg) 73 86 89 97
Cooling Rate 0.1–99.9°C/min
Heating Rate 0.1–12°C/min
Temperature Uniformity <2°C
Control System Microcomputer Control
Program Control Sample Temperature / Chamber Temperature
Display 10-inch Touchscreen
Available Programs 6 Preset Programs + 20 User-Defined Programs

Top-Opening Models

Model CX 26 CX 90 CX 150
Temperature Range +50°C to -180°C +50°C to -180°C +50°C to -180°C
Internal Dimensions (mm) 476 × 184 × 340 476 × 552 × 340 476 × 767 × 380
Overall Dimensions (mm) 701 × 769 × 539 701 × 1244 × 570 711 × 1444 × 584
Packaging Dimensions (mm) 810 × 870 × 680 810 × 1350 × 710 820 × 1550 × 730
Volume (L) 26 90 150
Number of Racks 9 27 45
0.25 mL Straws 900 2700 4500
0.5 mL Straws 630 1890 3150
Net Weight (kg) 40 62 140
Cooling Rate (°C/min) 0.1–99.9 0.1–99.9 0.1–99.9
Heating Rate (°C/min) 0.1–12 0.1–12 0.1–12
Temperature Variation <2°C <2°C <2°C
Control System Microcomputer Control Microcomputer Control Microcomputer Control
Temperature Control Modes Sample Temperature / Chamber Temperature Sample Temperature / Chamber Temperature Sample Temperature / Chamber Temperature
Display 7-inch Touchscreen 10-inch Touchscreen 10-inch Touchscreen
Available Programs 6 Preset Programs + 20 User-Defined Programs 6 Preset Programs + 20 User-Defined Programs 6 Preset Programs + 20 User-Defined Programs
Door Opening Type Top-Opening Top-Opening Top-Opening
Door Seal Special Silicone Rubber Seal Special Silicone Rubber Seal Special Silicone Rubber Seal
Cryogen Liquid Nitrogen Liquid Nitrogen Liquid Nitrogen
LN₂ Consumption per Cycle (L) 6–8 8–10 13–15
Heating Power 2.5 kW 3 kW 3 kW
Power Supply AC 220 V, 50 Hz AC 220 V, 50 Hz AC 220 V, 50 Hz
Gross Weight (kg) 119 186.5 —

The tables provide model-specific dimensions, capacity, temperature range, cooling and heating rates, control configuration, and other technical parameters. Please refer to the specifications for the selected model when evaluating compatibility with your samples and workflow.

Technical Notes

Sample Capacity: Listed capacities are based on the specified sample format and compatible loading configuration. Actual usable capacity depends on the holders, racks, and loading arrangement used.

Cooling and Heating Rates:The specified rates describe the system's adjustable temperature-change capabilities. Actual sample temperature profiles depend on the selected program, sample characteristics, loading conditions, and operating setup.

Temperature Control:Sample-temperature and chamber-temperature control are different control modes. Select the mode according to the requirements of your freezing protocol.

Temperature Uniformity / Variation:Refer to the applicable model specifications and the manufacturer's definition of each measurement when comparing temperature performance.

Liquid Nitrogen Consumption:The listed consumption per cycle should be evaluated against the model and applicable operating conditions. Confirm expected consumption for your intended freezing program with the manufacturer.

How Controlled-Rate Freezing Works

A controlled-rate freezing cycle follows a defined temperature program to prepare biological samples for subsequent cryogenic storage.

Step 1 — Prepare the Samples

Load the samples using compatible racks, holders, or containers, following the applicable sample-handling procedure.

Step 2 — Select the Freezing Program

Choose an appropriate preset or user-defined program based on the established protocol for the sample type.

Step 3 — Run and Monitor the Cycle

The freezer regulates the temperature according to the selected program while monitoring the configured sample or chamber temperature.

Step 4 — Transfer Samples to Cryogenic Storage

After the freezing cycle is complete, transfer the samples to suitable long-term storage equipment in accordance with the relevant handling and storage protocol.

Controlled-rate freezing and long-term cryogenic storage serve different purposes: the freezer manages the sample-freezing process, while the storage system maintains samples under the required storage conditions.

How to Choose a Controlled Rate Freezer/h2>

The right model depends on the sample format, required batch capacity, and laboratory workflow—not capacity alone.

Start with Your Sample Format

Identify whether you primarily process cryovials, blood bags, straws, or other compatible sample containers. Confirm that the selected model supports the required holders and loading arrangement.

Estimate Your Batch Capacity

Compare the number and type of samples processed in a typical cycle. Use the model-specific capacity figures in the technical tables to narrow down the options.

Check Laboratory Space and Loading Requirements

Consider the freezer's overall dimensions, chamber dimensions, opening direction, and the space needed for routine loading and operation.

Confirm Protocol and Operating Requirements

Review the required temperature range, cooling and heating rates, temperature-control mode, available programs, and power supply. For liquid-nitrogen-cooled models, also consider the stated LN₂ consumption per cycle.

If your sample format or freezing protocol requires a non-standard configuration, provide the sample type, container dimensions, target batch size, and protocol requirements for technical evaluation.

Discuss Your Controlled-Rate Freezing Requirements

Choosing a controlled rate freezer involves more than matching a capacity figure. Sample compatibility, freezing protocols, chamber configuration, and daily processing needs all affect model suitability.

Contact TcCryo with your sample format, batch requirements, and protocol specifications. Our team can help you review the available CX Series configurations and identify models for further technical evaluation.**CTA: Request a Technical Consultation**

Related Cryogenic Equipment

After controlled-rate freezing, biological samples may require suitable equipment for long-term cryogenic storage. Explore related TcCryo equipment according to your sample type, storage capacity, and application requirements.

- **Liquid Nitrogen Storage Tanks**

for cryogenic storage of compatible samples.

- **Vapor-Phase and Liquid-Phase Cryogenic Storage Systems**

for applications requiring a suitable vapor- or liquid-phase storage configuration.

- **Liquid Nitrogen Supply tank**

for laboratory workflows that require a dedicated liquid nitrogen supply.

Select related equipment based on your storage requirements and sample-handling procedures.

Frequently Asked Questions

Q1: What is the difference between a controlled rate freezer and a liquid nitrogen storage tank?
A controlled rate freezer regulates the cooling rate during sample freezing, while a liquid nitrogen storage tank maintains samples under cryogenic conditions after freezing. They serve different stages of the cryopreservation process and are commonly used together in laboratory workflows.
Q2: Can the CX Series accommodate different cryovial and blood bag sizes?
Yes. The CX Series accommodates different cryovial and blood bag sizes, depending on the freezer model and compatible sample rack configuration. However, different container sizes cannot be used interchangeably in the same rack configuration. Select the appropriate rack based on your sample container dimensions.
Q3: Can a controlled rate freezer guarantee cell viability after thawing?
No. A controlled rate freezer controls the cooling process but cannot guarantee post-thaw cell viability. Cell type, cryoprotectant formulation, sample preparation, and thawing procedures also affect the final results.
Q4: What are the installation requirements for a controlled rate freezer?
A controlled rate freezer requires a suitable liquid nitrogen supply, an appropriate electrical connection, and adequate installation space and ventilation. Before installation, confirm the model-specific LN₂ supply pressure, connection specifications, power requirements, and required operating clearances.
Q5: What should I check before purchasing a controlled rate freezer?
Before purchasing, review the technical specifications, available test documentation, and factory inspection records. Also confirm the selected model, processing capacity, sample rack configuration, and optional accessories. For procurement planning, check the warranty terms, delivery lead time, spare parts availability, and after-sales technical support.