Custom KF Flange and Open-Mouth Liquid Nitrogen Containers

KF Flange Liquid Nitrogen Container
liquid nitrogen container caliber design
KF Flange Liquid Nitrogen Container
liquid nitrogen container caliber design

KF Flange and Open-Mouth Customization for Specialized Applications

Standard liquid nitrogen containers may not meet every application’s connection or access requirements. TcCryo offers customized liquid nitrogen containers with KF flange and open-mouth configurations for applications that require specific neck openings, equipment interfaces, or structural arrangements.

The containers feature aluminum construction and vacuum insulation. Depending on the application, the neck opening, flange interface, connection position, and related structural details can be evaluated for customization.

For KF flange configurations, the mating interface must be confirmed against the intended equipment. For open-mouth configurations, the required opening dimensions and access requirements should be specified. Changes to the neck structure may affect thermal performance, so the final design should be evaluated against the application’s requirements.

                       
Chat Now DISCOVER NOW

Customization Options

KF Flange and Open-Mouth Configurations


  • 01

    KF Flange Customization:

  • For applications that require a compatible flange interface to connect the container with laboratory instruments, vacuum lines, or other system components.
  • Key details to confirm include the KF flange specification, mating dimensions, connection position, and container neck opening. A flange designation alone does not guarantee compatibility with every connected system.
  • 02

    Open-Mouth Customization:

  • For applications that require a specific container opening or additional access space without a KF flange connection.
  • Customization can be evaluated according to the required neck-opening diameter, the dimensions of components passing through the opening, and the intended operating arrangement.
  • 03

    Design Evaluation:

  • Both configurations require the intended application and relevant dimensions to be reviewed before production. Where available, equipment drawings, interface drawings, or reference photos can help clarify the requirements.
Multiple necks Liquid Nitrogen Container

Custom Container Neck Opening Sizes

50 mm, 80 mm, and 125 mm Options

TcCryo can evaluate container configurations with 50 mm, 80 mm, and 125 mm neck openings, depending on the required design.

These dimensions refer to the container neck opening, not necessarily the KF flange size. The neck opening and flange interface are separate design considerations and must be confirmed independently. When specifying an opening, consider the mating equipment, the dimensions of components passing through the opening, and the access required for installation or operation.

The final neck dimensions, flange configuration where applicable, and related structural details are subject to technical evaluation and drawing approval.

Custom Container Design Process

From Requirements to Approved Specifications

01. Submit Requirements

Share the required capacity, intended application, preferred configuration, neck-opening dimensions, and available equipment drawings or photos.

02. Technical Evaluation

Review the proposed configuration and identify the dimensions, connection details, and structural requirements that need to be confirmed.

03. Confirm Design and Interface

Clarify the container configuration, neck structure, KF flange interface where applicable, and other agreed specifications.

04. Approve Technical Drawings

Review and approve the technical drawings and specifications before production.

05. Production

Manufacturing proceeds according to the technical drawings and specifications confirmed by both parties.

Any changes to the approved design should be reviewed before production.

Use and Safety Considerations

Confirm Compatibility Before Use

Customized liquid nitrogen containers must be selected and used according to their confirmed specifications and intended application.

Verify connection compatibility:

For KF flange configurations, confirm flange dimensions, sealing components, and mating equipment requirements before installation.

Check opening requirements:

For open-mouth configurations, confirm that the opening dimensions and available access meet the intended operating requirements.

Use cryogenic-compatible components:

Any connected components or accessories must be suitable for the intended low-temperature conditions.

Avoid unapproved modifications:

Drilling, cutting, or other unauthorized structural changes may affect container integrity and thermal performance.

Review integrated system requirements:

If the container is connected to vacuum lines, piping, or other system components, assess the complete configuration for applicable pressure, venting, and safety requirements. Do not assume a standard storage container is suitable for a pressurized or enclosed system.

Follow operating instructions:

Use appropriate cryogenic personal protective equipment, ensure adequate ventilation, and follow the product manual and applicable safety procedures.

Confirm the suitability of the complete configuration before installation or operation.

Related Cryogenic Equipment

Laboratory Liquid Nitrogen Storage Containers

Explore liquid nitrogen containers for laboratory sample storage and review the available configurations for your application.

Liquid Nitrogen Supply Tanks

Explore liquid nitrogen supply equipment for applications requiring a compatible liquid nitrogen storage and delivery arrangement. Confirm system requirements and connection compatibility before selecting a configuration.


Request a Custom Liquid Nitrogen Container Solution

Need a liquid nitrogen container with a customized KF flange or open-mouth configuration? Share your required capacity, neck-opening dimensions, intended application, and relevant interface requirements. Drawings or photos can help clarify the design.

TcCryo can review the requirements and assess a suitable configuration based on the confirmed technical specifications.

Frequently Asked Questions

Q1: Can both KF flange and open-mouth configurations be customized?
Yes. TcCryo can customize both KF flange and open-mouth configurations according to your application requirements. The neck opening, connection details, and structural dimensions should be confirmed before production.
Q2: Will a customized neck affect static evaporation performance?
It may. Changes to the neck structure or interface can affect the container's thermal performance and static evaporation rate. If you have a specific evaporation rate requirement, please provide it during the design stage so it can be considered in the technical evaluation and verified through applicable testing.
Q3: Can the neck opening be changed without changing the container's overall dimensions?
In some cases, yes. Feasibility depends on the requested opening size and the existing container design. TcCryo will need to assess the available space, structural requirements, and potential effect on thermal performance before confirming the design.
Q4: Can I reorder a customized container in batches later?