> PRODUCTS
Get A Quote

Liquid Nitrogen Dry Shippers

dry shipper container
dry shipper tank
ln2 shipper
dry shipper vacuum flask
dry shipper container
dry shipper tank
ln2 shipper
dry shipper vacuum flask

Vapor-Phase Cryogenic Containers for Air and High-Speed Rail Transportation

TcCryo YDH liquid nitrogen dry shippers are designed for the transportation of biological samples by air and high-speed rail, subject to applicable carrier requirements. Their internal absorbent material retains liquid nitrogen and supports vapor-phase cryogenic conditions during transit, helping reduce the risk of liquid nitrogen spillage if the container is tilted.

Depending on the model and compatible storage configuration, they can be used to transport biological materials such as cells, frozen semen, embryos, tissues, and diagnostic samples.

                       
Chat Now DISCOVER NOW

Core Features of TcCryo Dry Shippers

  • 01

    Absorbent-Based Cryogenic Design:

  • An internal absorbent material retains liquid nitrogen to support vapor-phase cryogenic transportation. This design distinguishes a dry shipper from a conventional liquid nitrogen container that holds free liquid nitrogen.
  • 02

    Vacuum-Insulated Structure:

  • The vacuum-insulated structure helps limit heat transfer and supports cryogenic holding performance. Refer to the model specifications for holding-time data under the stated test conditions.
  • 03

    Internal Sample Storage Configuration:

  • Different models accommodate compatible sample storage configurations. Refer to the model specification table for available canisters, racks, and sample capacity when evaluating a product for your application.
  • 04

    Safety Lock and Optional Transport Case:

  • Each dry shipper is equipped with a safety lock. A protective transport case is available as an optional accessory and can be paired with any model. Confirm your preferred configuration when ordering.
dry nitrogen tank

Dry Shipper Models & Key Specifications

Compare the available TcCryo dry shipper models to review their holding-time performance, sample capacity, and compatible internal configurations.

Model YDH-2-35 YDH-3-50 YDH-4-80 YDH-6-80 YDH-10-125 YDH-15-216 YDH-25-216
Effective volume (l) 2 3 4 6 10 15 25
Liquid nitrogen adsorption (l) 1 1.3 1.8 2.4 6 7 10
Static evaporation rate (l/d) 0.1 0.15 0.19 0.21 0.4 0.89 0.89
Working days 9 9 9 11 15 7 11
Barrel size (mm) φ25*120 φ47*200 φ76*276 φ76*200 81*85*225 139*141*168 139*141*280
2ml cryotubes quantity N/A N/A N/A N/A 100 300 500
25-grid cryobox quantity N/A N/A N/A N/A 4 N/A N/A
100-grid cryobox quantity N/A N/A N/A N/A N/A 3 5
50ml blood bag quantity N/A N/A N/A N/A 6 N/A 11
250ml blood bag quantity N/A N/A N/A N/A N/A N/A 11
Caliber(mm) 35 50 80 80 125 216 216
Height(mm) 410 465 505 500 540 590 665
O.D(mm) 180 224 224 283 304 385 375

Parameter Guide

Liquid Nitrogen Absorption Capacity

The reference amount of liquid nitrogen that can be absorbed by the internal absorbent material. This value does **not** represent the usable sample storage volume.

Working Time

The reference working time under specified preparation and test conditions. It does **not** represent guaranteed actual logistics time or transportation duration.

Sample Capacity

The actual loading capacity depends on sample container dimensions and internal configuration. It should not be determined solely by the usable internal volume.

*Actual performance may also be affected by pre-cooling and absorption conditions, ambient temperature, sample loading, lid opening, and transportation conditions.*

How to Choose the Right Dry Shipper

Selecting a dry shipper starts with the samples being transported and the requirements of the complete journey.

1. Identify the Sample Type and Application

Determine which biological materials need to be transported and confirm that the selected model is suitable for the intended application.

2. Determine the Required Sample Capacity

Estimate the number of samples per shipment and compare the capacity and compatible storage configuration listed in the model specification table.

3. Match the Holding Time to the Transportation Schedule

Consider the expected journey duration, including transfers, waiting periods, and potential delays. Compare the complete schedule with the model's stated holding time and applicable test conditions.

4. Confirm the Required Configuration

Review the model's listed storage accessories and choose an optional protective transport case if needed. Confirm that the selected configuration accommodates your sample containers.

5. Evaluate the Product Range for Your Business

For distributors, compare the available models and configurations against the requirements of your target customers, such as laboratories, IVF facilities, animal breeding organizations, and other users with compatible biological sample transportation needs.

Contact TcCryo to discuss model availability and product details for your intended market.

Dry Shipper vs. Conventional Liquid Nitrogen Transport Tank

The main difference lies in their intended transportation applications: dry shippers are designed for transporting biological samples and may be suitable for air and high-speed rail transportation, subject to carrier requirements, while conventional liquid nitrogen transport tanks are generally used for road transportation and other suitable applications.

Comparison Dry Shipper Conventional Liquid Nitrogen Transport Tank
Primary purpose Cryogenic transportation of compatible biological samples Transportation or transfer of liquid nitrogen, depending on the tank design
Transportation applications May be suitable for air and high-speed rail transportation, subject to carrier requirements Generally intended for road transportation or other suitable transport applications; air and high-speed rail acceptance must not be assumed
Liquid nitrogen retention Internal absorbent material retains liquid nitrogen for vapor-phase transportation Holds free liquid nitrogen inside the tank
Main selection factors Sample compatibility, sample capacity, holding time, and transportation duration Required liquid nitrogen capacity, intended use, and transport conditions
Preparation Requires the specified liquid nitrogen absorption and preparation process before sample loading Requires preparation according to the specific tank's instructions

Which type suits your application?

Transporting biological samples by air or high-speed rail: Consider a compatible dry shipper and confirm acceptance requirements with the airline, railway operator, or logistics provider before shipment. Transporting or transferring liquid nitrogen by road: Consider a suitable conventional liquid nitrogen transport tank designed for that purpose.

Explore our Liquid Nitrogen Transport Containers for applications involving liquid nitrogen transport or transfer.

Dry Shipper Preparation and Transportation Requirements

Prepare the dry shipper according to the instructions supplied with the specific model before loading samples.

Step 1: Fill with Liquid Nitrogen

Fill the dry shipper with liquid nitrogen according to the product instructions so that the internal absorbent material can absorb the liquid nitrogen.

Step 2: Allow the Absorbent Material to Complete Absorption

Allow sufficient time for the absorbent material to absorb the liquid nitrogen. Follow the preparation procedure and duration specified for the selected model.

Step 3: Remove Residual Free Liquid Nitrogen

After the absorption process is complete, remove residual free liquid nitrogen according to the product instructions before loading samples.

Step 4: Load the Samples

Place compatible sample containers in the designated storage positions. Follow the sample-loading instructions and use the appropriate internal configuration for the selected model.

Step 5: Complete the Pre-Transport Inspection

Check that the preparation process is complete, samples are properly positioned, and the unit and required packaging are ready for transportation.

Air and Other Transportation Requirements

A properly prepared dry shipper may be suitable for certain air and other transportation applications, subject to applicable requirements. Acceptance depends on the carrier, route, shipment contents, preparation, packaging, and applicable regulations.

Before shipping, confirm the current requirements with the airline or logistics provider. Follow the applicable preparation, packaging, marking, and documentation instructions for the shipment.

Related Products

Explore other TcCryo liquid nitrogen containers and accessories for laboratory storage, biobanking, animal breeding, and transportation.

Aluminum Lab Dewars

Designed for laboratory liquid nitrogen storage and related cryogenic applications.

Vapor-Phase / Liquid-Phase Cryogenic Storage Systems

Designed for high-capacity cryogenic storage of biological samples in biobanks and other sample storage facilities.

Liquid Nitrogen Tanks for Livestock Breeding (1–50 L)

Designed for frozen semen storage and handling in livestock breeding applications.

Dry Shippers Packaging Box

Protective cases for liquid nitrogen containers during handling and transportation.


Find the Right Dry Shipper for Your Needs

Looking for a dry shipper for biological sample transportation? Contact TcCryo for model recommendations and product details.

Frequently Asked Questions

Q1: Can samples remain temporarily inside a Dry Shipper after arrival?
Yes. Samples can remain inside a Dry Shipper temporarily after arrival, provided the model has sufficient remaining cryogenic holding time to maintain the required sample temperature. For longer-term storage, transfer the samples to suitable cryogenic storage equipment according to your sample management procedures.
Q2: Can different types of samples be transported in the same Dry Shipper?
Only samples stored in the same size and type of sample container can be transported in one Dry Shipper. For example, 2 mL cryovials can be transported together, but 2 mL and 5 mL cryovials cannot be loaded in the same unit. The same principle applies to other sample containers, such as frozen semen straws and blood bags.
Q3: Can a Dry Shipper be reused after transportation?
Yes. Dry Shippers are reusable and can be used for multiple sample transportation cycles. Follow the operating instructions for the specific model before each use.
Q4: When should I choose an optional transport protection case?
An optional transport protection case is useful when you need to carry your Dry Shipper between locations, such as when traveling to an airport or railway station. It provides additional external protection and makes the unit easier to carry during transit. TcCryo offers compatible protection cases for Dry Shipper models.
Q5: What should distributors consider when selecting Dry Shippers for their market?
Distributors should first identify the sample container types and sizes commonly used by their customers. They can then compare available Dry Shipper models based on container compatibility, storage capacity, and cryogenic holding time to determine which models best match their market's needs.