> PRODUCTS
Get A Quote

LN2 Supply Tanks

Self-Pressurized Liquid Nitrogen Tanks for Storage and Supply.

TcCryo LN2 supply tanks use a self-pressurizing design to store liquid nitrogen and deliver it through controlled internal pressure. No external pressure source is required. Available in vertical and horizontal configurations, they can supply liquid nitrogen to other LN2 containers, laboratory equipment, and compatible cryogenic applications.→ →Get a Supply Configuration

Vertical vs. Horizontal LN2 Supply Tanks: Which Should You Choose?

TcCryo LN2 supply tanks are available in vertical and horizontal configurations. Both are designed for liquid nitrogen storage and supply, while their installation layouts differ.

The choice mainly depends on available installation space, site conditions, and the required tank capacity.

Selection Factor Vertical LN2 Supply Tank Horizontal LN2 Supply Tank
Installation Layout Upright installation Horizontal installation
Space Requirements Requires sufficient vertical clearance and floor space Requires sufficient horizontal space and suitable installation support
Typical Installation Sites where vertical clearance is available Sites where installation height is restricted or a horizontal layout is preferred

Which Configuration Is Right for Your Site?

Choose a vertical tank when sufficient vertical clearance is available and its footprint suits the installation area. Consider a horizontal tank when site height is limited and sufficient horizontal space is available.

Both configurations provide the same basic liquid nitrogen storage and supply function. Final selection should also account for capacity, installation conditions, and connection requirements.

How to Choose the Right LN2 Supply Tank

Selecting an LN2 supply tank requires more than choosing a storage capacity. Liquid nitrogen demand, the desired replenishment interval, connection requirements, and installation conditions should all be evaluated.

01 Assess Liquid Nitrogen Demand

Estimate the amount of liquid nitrogen required per replenishment cycle and the total expected consumption over a typical operating period.

The tank should provide sufficient usable capacity for the intended demand while fitting the site's installation and operating requirements.

02 Determine the Required Supply Interval

Consider how often liquid nitrogen needs to be supplied to receiving tanks or equipment.

A larger-capacity tank may allow longer intervals between replenishment, depending on actual consumption and operating conditions. Select a capacity that balances supply needs with available space and replenishment arrangements.

03 Confirm Supply Connections and Receiving Equipment

Identify the tanks, laboratory equipment, or other systems that will receive liquid nitrogen. Confirm the required flow rate, connection type, interface specifications, and any relevant operating requirements.

Suitable connection components or adapters may be needed, depending on the receiving equipment and system configuration.

04 Verify Installation and Operating Conditions

Confirm available installation space, required tank orientation, access for operation and maintenance, and the site's applicable safety requirements.

For project-based applications, TcCryo can provide model recommendations based on liquid nitrogen demand, replenishment intervals, receiving equipment, and installation conditions.

Applications

TcCryo LN2 supply tanks provide liquid nitrogen storage and supply for laboratory and other compatible cryogenic applications. The appropriate configuration depends on liquid nitrogen demand, receiving equipment, and site conditions.

Laboratory LN2 Supply

For routine liquid nitrogen supply in laboratories, supporting LN2 storage containers, compatible equipment, and cryogenic workflows.

Replenishment of LN2 Storage Equipment

For transferring liquid nitrogen to compatible storage tanks and cryogenic equipment in research laboratories and life science facilities, according to the required connection and operating specifications.

Biobanks & Life Science Facilities

For supplying liquid nitrogen to compatible cryogenic storage equipment in biological sample storage facilities. The required supply arrangement depends on the storage system and its operating requirements.

Cryogenic Processes & Industrial Applications

For compatible processes and equipment that require a liquid nitrogen supply. Application suitability should be confirmed against the equipment's flow, connection, and operating requirements.

Get an LN2 Supply Configuration

Tell us about your application requirements. TcCryo can recommend a suitable LN2 supply tank configuration based on your liquid nitrogen consumption, replenishment needs, installation conditions, and receiving equipment.Get a Recommended Configuration | Request a Quote

Frequently Asked Questions

Q1: How do I determine the required tank capacity and estimate the replenishment interval?
A:Estimate the required capacity based on daily liquid nitrogen consumption and the desired replenishment interval, while allowing an appropriate reserve. TcCryo LN2 supply tanks are available in capacities ranging from 15L to 500L to support different liquid nitrogen storage and supply requirements.
Q2: What should I consider when filling the tank for the first time or after long-term storage?
A: Before normal filling, introduce a small amount of liquid nitrogen to pre-cool the inner vessel. The filling process should then be carried out according to the applicable operating instructions. Do not fill beyond 90% of the rated tank capacity to help prevent excessive pressure rise and liquid nitrogen overflow.
Q3: Can an LN2 supply tank be used with other cryogenic equipment?
A: Yes. LN2 supply tanks can be used to replenish laboratory dewars, vapor-phase storage systems, controlled-rate freezing equipment, and other cryogenic equipment. Common supporting components include valves, casters, level indicators, and liquid nitrogen transfer lines.
Q4: How long can an LN2 supply tank be used, and when should it be retired?
A: The expected service life depends on the tank design, operating conditions, maintenance, and applicable inspection requirements. For TcCryo models with a specified design or service life, the applicable product documentation should be used as the reference. If abnormal conditions such as extensive frosting, significantly increased evaporation, safety-valve malfunction, or inner-vessel leakage are observed, the tank should be inspected and evaluated before continued use.
Q5: What are the MOQ, lead time, and long-term supply options for bulk orders?
A: MOQ and lead time depend on the selected model and level of customization. For standard models, production planning can support predictable delivery. For larger or recurring orders, long-term supply arrangements and inventory planning can be discussed based on the customer's procurement requirements.
View LN₂ Refill Cylinders Catalog