> BLOG
Get A Quote

TcCryo at the 2026 Anhui Instrument Distributors Conference

2026-10-30 18:40:29

On October 23, 2026, representatives from Henan Tianchi Cryogenic Machinery Equipment Manufacturing Co., Ltd. traveled to Hefei to attend the Anhui Instrument Distributors Training Conference, organized by Instrument Knowledge Network.

At the event, TcCryo showcased two liquid nitrogen storage models, the YDS-10 and YDS-65, along with the YDZ-30 self-pressurizing liquid nitrogen supply tank. Sample storage and handling accessories, including cryogenic racks and canisters, were also displayed.

TcCryo liquid nitrogen tanks on display

Using these products as examples, the TcCryo team discussed practical questions with instrument distributors, including sample management, equipment placement, liquid nitrogen supply requirements, and neck opening sizes. Based on these discussions and common purchasing considerations among distributors, this article looks at four key questions related to liquid nitrogen equipment selection.

1. Three Products on Display, Each Designed for a Different Purpose

Liquid nitrogen tanks and supply equipment differ in capacity, structure, and function. Capacity alone is not enough to determine which model is suitable. Actual selection should also take into account sample management methods, accessory configurations, available space, and the intended use of the equipment.

Model Product Type Key Selection Considerations
YDS-10 10-liter liquid nitrogen tank Sample quantity, access frequency, accessory requirements, and placement space
YDS-65 Liquid nitrogen storage tank / lab dewar Total sample volume, cryogenic rack configuration, storage organization, and access space
YDZ-30 Self-pressurizing liquid nitrogen supply tank Supply application, working pressure, flow rate, usage frequency, and connection requirements

2. Four Practical Questions About Liquid Nitrogen Equipment Selection

1. When Sample Types Are Diverse but Storage Volume Is Limited, Should You Choose Several Small Liquid Nitrogen Tanks or One Larger Tank?

When a laboratory has a relatively small number of samples but multiple sample types, sources, or management requirements, there are two possible approaches: using several small liquid nitrogen tanks for separate storage or consolidating samples in one larger tank.

Several small liquid nitrogen containers make it easier to organize samples by category or intended use. However, having more units also means considering additional floor space, LN2 replenishment, and routine inspection work.

A larger liquid nitrogen storage tank allows samples to be stored centrally. In this case, cryogenic rack configurations, sample identification, and storage zones should be planned in advance to ensure accurate sample identification and convenient retrieval.

The right approach depends on the types and total quantity of samples, whether separate storage is required, and how frequently samples need to be accessed. These factors should be evaluated before determining tank capacity and accessory configurations.

YDS-10 portable liquid nitrogen tank and YDS-65 lab dewar

2. What Should You Consider When Placing a Large-Capacity Liquid Nitrogen Storage Tank?

When selecting a larger liquid nitrogen tank, it is important to consider not only whether its storage capacity meets the requirement, but also whether the equipment can be installed and operated conveniently.

Before purchasing, check the tank’s external dimensions, laboratory door width, passageway clearance, and handling route. This helps prevent situations where the equipment cannot be moved into its intended location after delivery.

You should also allow sufficient operating space for opening the lid and removing cryogenic racks or canisters. Make sure the selected accessories are compatible with the tank’s neck opening.

If samples will be organized using multi-level cryogenic racks, plan the storage zones and sample identification system according to the actual workflow.

Specific space requirements should be confirmed against the dimensions of the selected model, accessory structure, product instructions, and the layout of the installation site.

3. Can a YDZ Series Self-Pressurizing Liquid Nitrogen Tank Replace a YDS Series Storage Tank?

The YDZ self-pressurizing series and the YDS storage series are designed for different purposes.

The YDZ series is a liquid nitrogen supply tank designed to deliver LN2 to compatible containers or equipment. The YDS series, on the other hand, is designed for cryogenic sample storage and retrieval.

Therefore, the nominal 30-liter capacity of a YDZ-30 does not mean it can replace a YDS-30 liquid nitrogen storage tank for sample storage.

If a customer needs both sample storage and liquid nitrogen supply for other equipment, these two requirements should be evaluated separately before selecting the appropriate models and configurations.

For liquid nitrogen supply applications, key considerations include the receiving equipment, required working pressure, flow rate, usage frequency, and connection requirements. Refer to the technical specifications and operating instructions for the selected model to confirm compatibility.

TcCryo team discussing liquid nitrogen tank selection

4. How Do You Choose the Right Neck Opening? And How Should You Evaluate Evaporation Rate and Refill Intervals?

The neck opening mainly affects accessory compatibility and the convenience of sample access. It determines whether cryogenic racks and canisters fit properly and how easily samples can be retrieved.

When selecting a neck opening, first confirm the dimensions of the sample containers and accessories, along with the actual access requirements. A larger opening is not automatically better for every application.

The static evaporation rate is an important indicator of a liquid nitrogen tank’s static insulation performance. When comparing different models, check the corresponding technical data and test conditions. Parameters measured under different conditions should not be compared directly.

It is also important to understand that the static evaporation rate is measured under specified test conditions. It does not necessarily represent actual LN2 consumption during daily operation.

Actual refill intervals are also affected by factors such as how often the lid is opened, how long it remains open, the storage arrangement, and LN2 replenishment practices.

For applications involving frequent sample retrieval, prioritize neck opening and accessory compatibility, as well as ease of operation. For long-term storage, evaluate the static evaporation rate of the selected model alongside actual operating conditions to estimate LN2 consumption and plan replenishment intervals.

3. Four Things Distributors Should Confirm Before Recommending Liquid Nitrogen Equipment

Distributors do not need to recommend a specific model as soon as a customer makes an inquiry. It is more effective to first understand the storage requirements, operating methods, installation conditions, and liquid nitrogen supply needs.

Once these details are clear, distributors can narrow down the available options by checking product specifications and accessory configurations.

What will be stored, and how much? What types of samples are involved, and how much storage capacity is required?

How will the equipment be used? How frequently will samples be accessed? Are cryogenic racks or canisters needed?

What are the installation conditions? Where will the equipment be placed? Are the available operating space, door width, and handling route sufficient?

Is liquid nitrogen supply also required? What are the supply target, pressure, flow rate, and usage frequency?

Having this information helps distributors narrow down the selection and explain the suitability of different models and configurations after verifying the relevant technical specifications.

TcCryo team presenting liquid nitrogen storage solutions

About TcCryo

Henan Tianchi Cryogenic Machinery Equipment Manufacturing Co., Ltd. specializes in the manufacturing of liquid nitrogen tanks and cryogenic equipment. Its product range includes storage-type liquid nitrogen tanks, self-pressurizing liquid nitrogen supply tanks, cryogenic transport equipment, and large-capacity biological sample storage systems.

These products serve applications such as laboratory sample preservation, livestock breeding, and large-scale biological sample storage.

TcCryo will continue to provide product information and selection support based on the practical requirements of different applications. For model-specific capacity, neck opening dimensions, supply parameters, and accessory configurations, please refer to the corresponding technical documentation.

For product configuration details or assistance with model selection, contact TcCryo to learn more.

TcCryo would also like to thank Instrument Knowledge Network for organizing the event and the industry partners who visited the booth and took an interest in our products.